125E CLEANspace Decontamination Showers Abatement New York, OSHA

125E 5-Stage Decontamination Shower Enclosure Asbestos Lead Enclosure for Abatement Professionals. Specification page.

CLEANspace by qüb9
 

Model 125E

PORTABLE DECONTAMINATION SHOWER SYSTEM 5-STAGE PERSONAL & WASTE REMOTE / ATTACHED

Meets/Exceeds* NYSDOL, Illinois & OSHA Regulations

 
 

FOR HAZWOPER & ABATEMENT PROFESSIONALS

* 12 Workers in New York & NYC pursuant to NYCRR Title: 12 Part 56 SUBPART 56-7.5(b)(c)(d); All others: OSHA Asbestos Regulation: 29 CFR Part 1926.1101.

Features

125E 5-Stage Portable Remote / Attached Decontamination Enclosures provide professional asbestos / lead abatement contractors with safe, convenient plug-and-play operation and an accelerated return-on-investment. The 125E is the most cost-effective, efficient and ergonomic 12-worker (NYDOL) personal decontamination platform available.

Capacity: 12-workers per shift.

Useful Life: 20+ years; built to withstand the rigors of global inter-modal shipping.

Warranty: 10-Year Warranty with Parts and Labor.

Low Maintenance: Change filters.  No 6-mil plastic, tape, corrosion or inspection issues in New York.

Deployment: Anywhere; average contract cost to transport 30-miles by conventional tilt-bed tow truck: $116.00; placement within inches - no labor, registration, plates, insurance or OTR(over-the-road) liability.

Professionalism: Industrial durability; Institutional quality and appearance.

Plug and Play: Attach supply hose and power cord.

Construction: Welded steel structure with non-permeable coatings. 

 

Reductions: Deployment costs; maintenance labor; consumables, consumable waste, service-labor; waste decontamination construction time and materials; decommission time and labor; depreciation.

Eliminates: In-house deployment labor / driver; trailer titles; taxes; plates; OTR/tow package insurance; wiring issues; 6 mil plastic / tape(NY); unit decay; inspection issues related to both unit quality control and shift size

 

Additional Features:

Materials: Structure made of A588 high-corrosion-resistance structural steel designed for marine / shipping environments; industrial enamel finish; Interior coated with impermeable direct to metal epoxy; 1.125” marine-rated subfloor sealed with epoxy and rubberized non-skid.

Equipment / Wash Room: Boot storage shelves, hooks, suit disposal, easily accessible mechanicals, 2-gang GFCI protected receptacles, hose bib, cold-weather purge system, shelves and enclosed storage containers for bags, filters and miscellaneous job site consumables.

AirLock 1: 14 SF; >36” curtain-to-curtain, 100% overlap 108 mil AirCurtains or, Triple-Curtains.

Shower Space (2 showers): On demand hot water, epoxy DTM shower walls, floor grids and 36-gallon gray-water reservoir, water-saving shower heads, hot/cold adjustable mixing-valve at the tap. Fire-retardant air-curtains simultaneously isolate contaminants, water and humidity. Wall-mounted shower-gel dispenser, respirator and hard hat hooks, filter disposal ports are standard in each shower.

AirLock 2: Towel bars, respirator and hard-hat hooks.

Clean Room: 64 SF with curtained Privacy Room; 12-wall-mounted lockers (12”W x 30”H x 12”D) installed 20" above finished floor for easy cleaning. UHMW polyethylene dressing bench with Stainless base, AirCurtains for privacy and air-control. Clean storage for Personal Protection Equipment(PPE), 12-wall-mounted jacket / respirator hooks, towel depository, ceiling-mounted electrical panel and in-line water heater near exterior door, USB device charging ports. 

Water Filtration: 3-Stage in-series 50/20/5 micron gray-water filtration system with GFCI protected pump and 5/8” discharge.

Optional: holding tank.

Regulatory Compliance Citations

USDOL: OSHA: Asbestos Regulations: 29 CFR Part 1926.1101(j)(1). w/ optional negative and make-up air system.

NYSDOL: 12 NYCRR Part 56 SUBPART 56-7.5(b)

NYCDEP: BEC: Title 15, Chapter 1. Subchapter A., F. Part 2. §1-82, §1-83.P

Illinois EPA:

Specifications 

Structure: A588 high-corrosion resistant steel superstructure and partition walls.

Exterior: 8’-0” W x 8’-6” H x 20’-0” L

Interior: 7’-10” W x 7’-10” H x 19’-10” L

Exterior Coatings: DTM primer; UV stable industrial enamel; Custom colors available.

Interior Coatings: Impermeable epoxy coating, anti-microbial protectant.

Subfloor: 1.125” marine-rated plywood with epoxy coating, rubberized non-skid.

Transport Payload: 4,000 lbs. tools & equipment; 112 SF / 784 CF.

Working Storage: 2,250 lbs. tools & equipment; 52 SF / 350 CF.

Tare Weight: 4,420 lbs.

AirCurtains: PVC 100% overlap transparent 108 mil retardant NFPA B-s3-d0 fire class

External Power: 2/3 oil-resistant pigtail with locking, weather-proof connection;

On-board Power: Ceiling mounted EMT with GFCI protected devices.

Power2: Optional: generator with isolated enclosure / fuel storage;

Lighting: LED fixtures rated for wet conditions, warranted for life of unit;

Water Supply: 50’ x 5/8” NPT, NSF approved supply hose;

Water Heater: Inline high-efficiency on-demand electric water heater

Water Filtration: Guardian™ PuroLoc™ 3205 3-stage 50/20/5 Micron gray-water filtration;

Reservoir: 36-gallon surplus reservoir;

Holding tank: Optional;

Discharge: Not included: 5/8” standard garden hose;

Leveling: Built-in spirit levels for leveling assistance;

Graphics/Branding: Options available in vinyl or custom paint by quotation;

Ladder Racks: Optional

Negative Air Machine, HVAC: Optional 

10-Year Warranty with Transferable Option

For a period not to exceed Ten-Years(10-Years) from the date of manufacture, qüb9 will repair or replace for the Original Buyer or Transfer Buyer, at our expense, any manufacturer’s defect in workmanship. Upon the occasion of: (1) immediate written notice to us by (a) the Original Purchaser or, (b) the Transfer Purchasor and, after: (2) our inspection of the subject defect and determination of liability by us, we will at our option repair or replace the defective component(s). This includes labor and materials at our facilities or, at qüb9 authorized facilities in your area. qüb9 shall not be responsible for shipping, handling or delivery in either direction of unit to any location for any purpose under this Warranty. 

 

Printed Materials, Copyright Notice & Disclaimer:

©2016, qüb9, inc. All Rights Reserved. No reproduction of any portion of this material is permitted without express written permission of qüb9, Inc. Illustrations and specifications contained in this material are based on the latest information available at time of printing. qüb9, Inc. reserves the right to make changes to product designs, specifications, materials, colors, at any time, without notice.

 

Portable, Mobile, Personal, Personnel, Enclosure, Asbestos, Lead, Abatement, Mold, Remediation, Decon, Decontamination, Personal, shower, containment, containment area, disposal, showers, Shipping Container, complies, compliant, certified, approved, OSHA, HAZMAT, waste, waste decontamination, large job, small job, professional, GSA, US Government, ship, first responder, emergency, HAZWOPER, Demolition, Construction, Price, Delivery, Distributor, Cornerstone Training Institute, PACNY, New York State Department of Labor, NYSDOL, NYCDEP, environmental, protection, US, USEPA, NIOSH, EPA, Industrial, Airlock, Air Lock, negative air, HEPA, Clean room, water filtration, Equipment room, shipping container, conex, connex, box, intermodal, sea box, sea, Alabama, Alaska, Arizona, Arkansas, California, Colorado, Connecticut, Delaware, Florida, Georgia, Hawaii, Idaho, Illinois, Indiana, Iowa, Kansas, Kentucky, Louisiana, Maine, Maryland, Massachusetts, Michigan, Minnesota, Mississippi, Missouri, Montana, Nebraska, Nevada, New Hampshire, New Jersey, New Mexico, New York, North Carolina, North Dakota, Ohio, Oklahoma, Oregon, Pennsylvania, Rhode Island, South Carolina, South Dakota, Tennessee, Texas, Utah, Vermont, Virginia, Washington, West Virginia, Wisconsin, Wyoming, Toronto, ON, Ontario, Mississauga, Kingston, Ontario, Montreal, OSHA Asbestos Regulation: 29 CFR Part 1926.1101, NYCRR Title: 12 Part 56